新产品 VF-5ht UltiMetal™高温不锈钢气相GC毛细管柱
独特的高温不锈钢气相GC毛细管柱,在保证材料惰性的同时,提高键合的强度, 从而延展了使用的温度上限,延长色谱柱的寿命 更低的流失,保证了更高的信噪比。
biodesiel-3.jpg
Unique extremely durable column
VF-5ht UltiMetal™: Stabilized Liquid Phase稳定的固定相
Phase stability is a major requirement for high temperature GC. In comparison with several commercially available high temperature GC columns (based on a 5% phenyl, 95% polydimethylsiloxane phase), the lowest bleed performance and the shortest stabilization time is achieved by VF-5ht UltiMetal.

VF-5ht UltiMetal™: Crosslinking先进的交联技术
In GC columns, crosslinking in the stationary phase makes it more stable at higher temperatures, resulting in low column bleed. However, too many crosslinks make the stationary phase less liquid, giving rise to degraded peak shapes even for inactive compounds such as alkanes. Varian’s advanced phase chemistry keeps the stationary phase of the VF-5ht UltiMetal very stable, without limiting chromatographic performance. An example of the superiority of the column is apparent in the analysis of Polywax® 655, with excellent peak shape of the components eluting at higher temperature.
The basis of the VF–5ht UltiMetal is a stainless steel capillary – extremely durable when operating at high temperatures. Varian’s UltiMetal technology renders the stainless steel inert and enhances the bonding of the stationary phase. The result is long column lifetime with excellent peak shape and low column bleed for the best detection limits at high temperatures. The UltiMetal column provides the highest signal to noise ratio and greatest productivity, so you can be very confident in having the best experimental results and the lowest cost per analysis.
Key benefits of the column主要优势: ·maximum temperature specification of 450 °C 最高使用温度为450摄氏度
·resistance to high temperatures, so you can spend more time gathering information and less time replacing broken columns ·stabilized liquid phase coating gives low bleed and low baselines for excellent trace analyses at high temperatures. Read More ·pre-installed retention gaps with leak tight and low dead volume couplings permit large sample volume injections for improved peak shape ·advanced phase chemistry keeps the stationary phase of the VF-5ht UltiMetal very stable, without limiting chromatographic performance.
相关应用:
VF-5ht UltiMetal™: Application Notes
Varian offers many of its public documents as PDF (Portable Document Format). PDF files can be read and printed. For detailed application information on Varian VF-5ht download a PDF version of the following application notes:
订货信息:
| VF-5ht UltiMetal |
|
|
|
|
Tmax Iso/Prog 430/450, Tmin -60 |
| Part No. |
Internal Diameter |
Length |
Df |
Guard 保护住 |
Bleed |
Asymmetry N/m |
|
(mm) |
(m) |
(um) |
|
(pA) |
|
| CP9090 |
0.25 |
15 |
0.1 |
|
4 |
1.14 3500 |
| CP9091 |
0.25 |
15 |
0.1 |
2 m x 0.53 m |
4 |
1.14 2500 |
| CP9092 |
0.25 |
30 |
0.1 |
|
7.5 |
1.14 3500 |
| CP9093 |
0.25 |
30 |
0.1 |
2 m x 0.53 m |
7.5 |
1.14 2500 |
| CP9094 |
0.32 |
15 |
0.1 |
|
6 |
1.14 2700 |
| CP9095 |
0.32 |
15 |
0.1 |
2 m x 0.53 m |
6 |
1.14 2500 |
| CP9096 |
0.32 |
30 |
0.1 |
|
12 |
1.14 2700 |
| CP9097 |
0.32 |
30 |
0.1 |
2 m x 0.53 m |
12 |
1.14 2500 |
|